logo
Shenzhen CN Technology Co. Ltd.. 86-135-3787-5415 Lizzy@smtlinemachine.com
99.999% high-purity box type PSA Nitrogen generator

99.999% high-purity box type PSA Nitrogen generator

  • Destacar

    high purity PSA nitrogen generator

    ,

    99.999% pure nitrogen generator

    ,

    YAMAHA nitrogen generator with warranty

  • Capacidade de nitrogênio
    1-100Nm3/h
  • Pureza de nitrogênio
    95%~99,999%
  • Pressão de nitrogênio
    0,5 ~ 0,8 MPa (aumento para alta pressão)
  • Ponto de orvalho de nitrogênio
    ≤-40°C (pressão atmosférica)
  • Controle fonte de alimentação
    0,2kW 220V 50Hz
  • Lugar de origem
    China
  • Marca
    CNSMT
  • Certificação
    CE- PSA Nitrogen
  • Número do modelo
    HN-4030
  • Quantidade de ordem mínima
    1 conjunto de máquina ou pedido misto também é aceitável Transporte: A granel ou contêineres
  • Preço
    Negociável
  • Detalhes da embalagem
    Caixas de exportação padrão e embalagens de madeira resistente são ambas opções
  • Tempo de entrega
    1-2 dias úteis
  • Termos de pagamento
    L/C, D/A, D/P, T/T, Western Union, MoneyGram

99.999% high-purity box type PSA Nitrogen generator

99.999% high-purity box type PSA Nitrogen generator

Chemical industrial: Cleaning, inertilizing and cata-lyzing for the pipeline, storage tank and etc Foodindustrial: packing, and sealing for juice, food oil,alcohol and beer.

Metal heat treatment: protection air of Anneal,quench, oxidation, sintering and etc.

Ship: Cleaning and nitrogen charging for vessels ofchemical cargo, natural oil cargo.

Medical: Cleaning and nitrogen charging for materi-al and product.

Rubber: The nitrogen protection fmanufacturing of rubber productsor the progress of manufacturing of rubber products.

Air delivery, Storage : powder anti-explosive, grain storing, mould and insects removing and etc.

Petro-leum and natural gas: Cleaning and protecting forthe tank and pipeline.

Painting: Avoiding fire, oxidization and N2 charging.

Enhance oil recovery: Inject N2 to the oil well andget residual oil.

Vegetable and fruit storage: Fresh and storing.

 

Technical principle of box type PSA nitrogen generator

 

The equipment relies on the principle of pressure swing adsorption (PSA) and air separation for nitrogen production, using high-quality carbon molecular sieves as the adsorption medium.
Compressed clean air is introduced into the adsorption tower. Under pressure, molecular sieves preferentially adsorb impurities such as oxygen and carbon dioxide in the air, while nitrogen cannot be adsorbed and can be retained and separated; During the decompression process, the adsorbed oxygen is desorbed and discharged, and the molecular sieve completes the regeneration cycle.
Two towers alternate between adsorption and desorption processes, continuously producing high-purity nitrogen gas with a stable purity of 99.999%, which meets the gas standards for SMT precision welding processes. The enclosed box structure of the whole machine isolates external impurities, ensuring stable and efficient nitrogen production process.

 

 

Main Feature

 

1.The material source is from the nature, the systemonly needs compressed air and power, so the cost ofpower and operation is less.

2.Nitrogen purity is easy to adjust, it is only affectedby the capacity, purity of normal nitrogen is at the rangeof 95%-99.99%(can be adjusted), purity of high nitrogenis at the range of 99%~99.999%( can be adjusted)

3.The system is automatic, quick starting and noneed to monitor. One button for start and stop, run 10-15minutes to generate the N2 air.

4.The working progress is easy, the configuration iscompact, the landing space is less and the environmentis wel-adapted.

5.Snow storm filling can avoid the damage of CMS.6.Digital flow meter has pressure compensation, it ishighly precise meter which can monitor the progress, itcan test quick flow and accumulate the total capacity.

 

Precautions for safe use of box type PSA nitrogen generator
1. Installation and Environmental Safety
Venue requirements: The equipment must be placed in a well ventilated, dry, and clean indoor environment, away from open flames, heat sources, corrosive gases, and dust sources. The ground must be level and load-bearing, with sufficient space reserved for maintenance and heat dissipation.
Power supply and grounding: Wiring must be done according to the rated voltage of the equipment, with reliable grounding to avoid voltage instability and leakage risks; It is strictly prohibited to connect wires privately or randomly, and the distribution box must be equipped with overload and leakage protection devices.
Pipeline and connection: Before installation, check all air pipes and valves for damage or air leakage, and conduct an air tightness test after connection; It is strictly prohibited to use unqualified or expired pipeline fittings to avoid nitrogen leakage.
2. Pre startup safety check
Status confirmation: Check whether the box door is completely closed and locked, confirm that there is no accumulation of debris inside the equipment, the cooling fan and temperature control system are normal, and there are no fault alarms.
Parameter verification: Confirm that the intake pressure, equipment set pressure, and purity parameters are all within the rated range, and that the pressure regulating valve and safety valve are in standard working condition.
Personnel preparation: Operators must be familiar with the equipment operating procedures and are strictly prohibited from operating without a license or violating regulations; Clean the surrounding area of the equipment before starting up, and prohibit stacking flammable materials.
3. Safety standards for operation process
Operation monitoring: During equipment operation, it is necessary to regularly observe instrument data such as pressure, purity, and temperature. If there is a sudden change in pressure, abnormal purity, or abnormal noise or odor, the machine should be stopped immediately for troubleshooting.
Prohibited illegal operations: It is strictly prohibited to open the box door or touch the internal high-temperature/high-pressure components during operation. It is also prohibited to modify equipment parameters or disassemble safety protection devices without authorization.
Nitrogen leakage protection: Nitrogen is an inert gas, and leakage can reduce the oxygen content in the environment. If a leakage is found, the machine should be immediately shut down for ventilation, and personnel should evacuate to a safe area. Treatment can only be carried out after the oxygen content returns to normal.
4. Maintenance and repair safety
Power off and pressure relief priority: Before any maintenance or repair operation, the power must be cut off, the internal pressure of the equipment must be evacuated, and there must be no residual gas before opening the box door for operation.
Standardize maintenance process: replacement of consumables such as filter cartridges and molecular sieves should be carried out according to the instruction manual cycle, using original factory accessories; During maintenance, be sure to label and warn the equipment to prevent accidental startup.
Anti static protection: When conducting maintenance in dusty environments, it is necessary to wear an anti-static wristband to avoid safety hazards caused by static sparks.
5. Shutdown and long-term storage safety
Normal shutdown: During shutdown, gradually release pressure and turn off the power according to standard procedures. It is forbidden to directly shut down the machine to avoid damage to components caused by pipeline pressure impact.
Long term storage: If the equipment is not in use for a long time, the internal gas should be emptied, and it should be sealed for moisture and dust prevention. The status of pipelines and electrical components should be checked regularly to prevent moisture and corrosion.

 

99.999% high-purity box type PSA Nitrogen generator 0

 
设备型号 设备产量 氮气纯度 尺寸L*W*Hmm 进气口径 出气口径 设备重量(kg) 电源
HN4010 10Nm3/h ≥99.99% 1300*950*1850 G1/2" G1/2" 500 AC220V/0.2KW
HN4020 20Nm3/h ≥99.99% 1400*950*1850 G1" G1/2" 600 AC220V/0.2KW
HN4030 30Nm3/h ≥99.99% 1500*950*1850 G1" G1/2" 700 AC220V/0.2KW
HN4040 40Nm3/h ≥99.99% 1600*1000*2000 G1" G1/2" 800 AC220V/0.2KW
HN4050 50Nm3/h ≥99.99% 1600*1200*2200 G1" G1/4" 1000 AC220V/0.2KW
HN4060 60Nm3/h ≥99.99% 1600*1200*2200 G1" G1" 1200 AC220V/0.2KW
HN4080 80Nm3/h ≥99.99% 1800*1400*2500 G1" G1" 1600 AC220V/0.2KW
HN4100 100Nm3/h ≥99.99% 2000*1600*2600 DN32 G1" 1800 AC220V/0.2KW
HN4150 150Nm3/h ≥99.99% 2200*1600*2700 DN40 G1" 2400 AC220V/0.2KW
HN4200 200Nm3/h ≥99.99% 2300*1600*2700 DN50 DN40 3000 AC220V/0.2KW
HN4250 250Nm3/h ≥99.99% 2400*1600*2700 DN50 DN40 4000 AC220V/0.2KW
HN4300 300Nm3/h ≥99.99% 2500*1600*2760 DN65 DN40 5600 AC220V/0.2KW
HN4400 400Nm3/h ≥99.99% 2700*1800*2900 DN65 DN50 6500 AC220V/0.2KW
HN4500 500Nm3/h ≥99.99% 3200*2400*3900 DN80 DN65 7500 AC220V/0.2KW
HN4600 600Nm3/h ≥99.99% 3500*2500*4000 DN80 DN65 8500 AC220V/0.2KW
HN4700 700Nm3/h ≥99.99% 3500*2500*4500 DN100 DN80 9500 AC220V/0.2KW
HN4800 800Nm3/h ≥99.99% 3800*2600*4500 DN100 DN80 11000 AC220V/0.2KW
HN4900 900Nm3/h ≥99.99% 3800*2600*5200 DN100 DN80 12000 AC220V/0.2KW
HN41000 1000Nm3/h ≥99.99% 4000*2800*5500 DN100 DN80 15000 AC220V/0.2KW

 

service life and reduce the frequency of failures.

  • Integrated and well-organized layout
  • The pipeline is neatly organized and the accessories are arranged in different zones, making it easy to quickly locate the fault location and efficiently troubleshoot problems.
  • There is a dedicated channel for maintenance
  • The fuselage is equipped with maintenance doors and reserved operation ports, which can be opened to access internal components, meeting the routine replacement operations of filter elements, molecular sieves, and valves.
  • Automated operation and maintenance are worry free
  • The intelligent control system automatically monitors pressure, purity, and temperature, and provides automatic alerts for abnormalities, eliminating the need for dedicated personnel to monitor and monitor daily operations.
  • Clear maintenance cycle
  • The replacement cycle of filter elements and adsorption consumables is fixed, and routine maintenance can be carried out according to the cycle. The maintenance process is standardized and easy to execute.
  • Cooling supporting operation and maintenance
  • Equipped with a built-in heat dissipation and temperature control system, it is necessary to regularly clean the dust accumulated in the heat dissipation vents to ensure the heat dissipation effect of the enclosed space and avoid high temperatures affecting operation.
  • Protective structure reduces human damage
  • The shell blocks bumps and accidental touches, and the electrical pipelines are not easily damaged. Daily inspections only require visual and parameter checks.
  • Fault controllable and easy to repair
  • Modular design of the structure allows for individual maintenance and replacement of single faults without the need for extensive disassembly, resulting in short downtime for maintenance.

99.999% high-purity box type PSA Nitrogen generator 1

Basic Cognition

What is the purity of nitrogen that can be achieved?
Purity adjustable, up to 99.999%, suitable for SMT precision production gas.
What is the difference between box type and open type models?
Sealed enclosure for dust and noise reduction, stronger protection, suitable for clean workshops; The space for heat dissipation and maintenance is relatively small.

 

Run and use
Can I work continuously 24 hours a day?
Support 24/7 uninterrupted gas production to meet the continuous gas supply needs of the production line.
Is the operating noise loud or not?
The box is equipped with sound insulation structure, which has low operating noise and does not interfere with workshop operations.
Can the gas production pressure and flow rate be adjusted?
Both can be flexibly set according to the on-site gas usage conditions, with strong adaptability to gas supply.

 

Quality malfunction
What is the reason for the sudden decrease in gas purity?
Excessive intake impurities, aging of molecular sieves, pipeline leaks, and unstable pressure can all lead to a decrease in purity.
How to deal with abnormal noise during equipment operation?
First, stop the machine and check the pipeline fasteners, valves, and fans to identify any foreign objects or looseness issues.
How to solve the problem of high water content in gas?
Replace the pre filter drying filter element on time and check the operating status of the drying system.

 

Maintenance and installation
Is daily maintenance troublesome?
The maintenance process is simple, with regular cleaning of the air vents and replacement of the filter element, resulting in low maintenance costs.
What are the mandatory requirements for maintenance and repair?
It is necessary to cut off the power and release the pressure before opening the box for operation. It is strictly prohibited to disassemble internal components while under pressure or with electricity.
How long is the service life of core consumables?
Under normal working conditions, carbon molecular sieves have a long service life, and the filter element can be replaced regularly according to the cycle.

 

Scenario and Security
What production scenarios are mainly applicable?
Commonly used in clean processes such as SMT surface mounting, reflow soldering, electronic packaging, and precision soldering.
What are the safety precautions when using?
Maintain ventilation and heat dissipation, strictly prohibit open flames from approaching, and promptly investigate nitrogen leaks through ventilation.
Is on-site nitrogen production advantageous compared to purchasing nitrogen?
Significantly save gas costs, provide stable and uninterrupted gas supply, and eliminate the need for gas cylinder storage and transportation management.

 

 

Contact Information
Phone: +8613537875415
Email: Lizzy@smtlinemachine.com
Address: Xintian Industrial Area, Baoan, Shenzhen City, China